Recommended Care of Your Mud-Sucker® Pump

Winter Storage

During freezing weather, it is especially important to follow these procedures to prevent ice from cracking the pump:

a) Drain all of the water (or liquid) from the pump body after use.

b) Follow motor or engine manufacturer’s storage instructions.

Outdoor Storage

a) Provide adequate cover with proper ventilation

b) Place the pump rod in the up position to drain water from the cavity above the diaphragm.

Effects

Any metallic equipment can be subject to water condensation as result of fluctuating ambient temperatures during storage, and this condensation can cause severe rusting which will either detract from the appearance of the equipment or contribute to premature failure.

Need for Proper Protection

Equipment that is to be stored (or installed but not started up and operated) for a long period of time should be given proper protection so that it will be in good operating condition when ready for use.  Equipment shipped by Wastecorp, has been protected in such a way that sheltered storage for three months before operation will cause no problems.

However, if field conditions are such that storage prior to operation should occur for longer than three months, the contractor or owner must make arrangements for additional protection beyond that supplied by the Wastecorp (manufacturer).

Customers should notify Wastecorp at the time of order if your pump will be inactive for longer than three months. In this event, the factory will take additional steps to protect your pump prior to shipment and any needed supplementary instructions will be attached.

Basis for Recommendations

The suggestions that follow are provided for guidance in securing satisfactory and trouble-free operation after long term storage, and are not to be regarded as an extension of standard warranty coverage.  They are on a generalized basis by product or component and the portions applying to each component or product should be used.  

A motor driven gear reducer, for example, will require reference to sections for gear reducers and sections for motors in determining the proper gear reducers and sections for motors in determining the proper storage conditions and protection required.

Regardless of how well protected the equipment may be, periodic inspection at intervals of one month or less should be made to determine whether or not the protection provided has been adequate.  If corrosion or deterioration of coatings, protective closures, etc., becomes apparent, corrective steps should be taken immediately to improve the protection.

Standard Pre-Shipment Preparation

Major machine components and motors have been wrapped with a reinforced plastic covering which should be left in place until the unit has been mounted in its permanent location indoors.  Continuing protection will be provided during installation of other equipment, area painting, etc., if the covering is left in place during attachment of piping and electrical connections, with slits or holes made where required to gain access for making such connections.

All exposed machine parts have a coating of anti-seize lubricant.  The diaphragm chamber and parts within it have been coated with anti-seize, which will also protect the walking pin bushings. The grease coatings and oil level in the lubricator should be maintained during storage.

The entire pump has been greased by Wastecorp prior to shipment.

All motors, gear boxes, and grease fittings have been lubricated according to their manufacturers’ specifications.  Grease fittings are covered, and should be left on their fittings and used to re-cap the fitting between lubrications.

More Tips
Safety Instructions    
Service
Storage
Receiving & Precautions
Care of Equipment
Moving & Handling    
Operating Instructions
Trouble Shooting
Maintenance
See all tips
Wastecorp.com logo
Plunger Pumps
Trash Pumps
Diaphragm Pumps
Submersible
Vertical Sewage
Split Case
Other High Volume
About Wastecorp Pumps
Markets
Training & Installation
Distributors
Other Wastecorp Products
Online Pump RFQ
Online Parts RFQ

© 2008 Wastecorp. All Rights Reserved. Use of this site is subject to certain
Terms of Use which constitute a legal agreement between you and Wastecorp.
Technical Support: 1.888.829.2783
E-mail: info@wastecorp.com
Site Map | Privacy Policy