• HPE Heavy Duty plunger pumps
  • Installation at an NYC DEP WWTP
  • Plunger pump installation in Maryland, USA
  • Plunger pump in Upstate NY USA
  • Plunger pump for the City of Chicago WWTP


Brochures & Documents

HPE 81™/HPE 941™ Series Specifications

Documents
Documents HPE 81/941 Specs Documents Plunger Pump Brochure  

Specifications
    HPE 81/941 HPE 82/942 HPE 83/943 HPE 84/944  
 
 
  No. of Plungers 1 2 3 4  
  Plunger dia (in) 9" 9" 9" 9"  
  Air Chambers (2) 9"x30" (2) 9"x30" (2) 9"x30" (2) 9"x30"  
  Flanged Connections 4" ANSI 125 # 4" ANSI 125 # 6" ANSI 150 # 6" ANSI 150 #  
  Driver Speed (RPM) 1800 1800 1800 1800  
  No. of Pin Positions 11 11 11 11  
  Max. Strokes/min 50 50 50 50  
  Max. Stroke Length (in) 7.25 7.25 7.25 7.25  
  Max. Suction Lift (ft) 20 20 20 20  
  Max. Total Head (ft) 240 240 180/240 140/240  
  Max. Capacity (GPM) 95 187 278 370  
  Eccentric Dia. (in) 12 12 12 12  
  Shaft Strength (PSI) 160,000 160,000 160,000 160,000  
  Pump Wt. (-Driver) 1255 1920 2650 3465  

HPE Series™ Pump Reviews

Overall Rating 4/5

High Performance 5 Pump Quality 5
Rating for My Application 4 Innovative 5
4/5

Military Base Sewage Pumps

Hallrman

From:
Seoul, South Korea
Application:
Sludge pumping
Average GPM:
235 GPM

Our mot recent order with you is for the HPE 942 with direct drive and guided plunger assembly. This is our fourth plunger pump upgrade and operations has provided positive feedback on this unit. So far, the guided plunger set up has saved on maintenance and parts.

4/5

Digester Sewage Pumps

DepENV

From:
Halifax, NS Canada
Application:
digester sewage
Average GPM:
210

We just replaced our old Carter plunger pumps with your new HPE 944 pumps. We got the upgraded packing and we see the difference in seal and operating efficiency.

5/5

Replaced Moyno PG pumps

Sander

From:
Greensboro, NC
Application:
Municipal Sludge
Average GPM:
89

Our facility got talked into replacing our plunger pumps with Moyno progressive cavity pumps. Was that ever a mistake. Since the amount of grit we pump varies depending on storm water, etc. we needed pumps to manage heavy grit and sludge at times. The Moyno's cost a fortune for spare parts and took three times longer to service. We replaced them all with three HPE-941's and our sewage transfer operations are back to normal.

HPE™ Series Features


sludge pump features
sewage pump features

HPE™ Series Pump Video

HPE 111™/HPE 1141™ Series Specifications

Documents
Documents HPE 111/1141 Specs Documents Plunger Pump Brochure

Specifications
    HPE 111/1141 HPE 112/1142 HPE 113/1143 HPE 114/1144  
 
 
  No. of Plungers 1 2 3 4  
  Plunger dia (in) 11"  
  Air Chambers (2) 9"x30"  
  Flanged Connections 4" ANSI 125 # 4" ANSI 125 # 6" ANSI 150 # 6" ANSI 150 #  
  Driver Speed (RPM) 1200(Belt Driven) - 1800(Direct Drive)  
  No. of Pin Positions 11  
  Max. Strokes/min 50  
  Max. Stroke Length (in) 7.25  
  Max. Suction Lift (ft) 20  
  Max. Total Head (ft) 170 170 130 95  
  Max. Capacity (GPM) 142 280 418 556  
  Eccentric Dia. (in) 12  
  Shaft Strength (PSI) 160,000  
  Pump Wt. (-Driver) 1450 2400 3600 4400  

Did You Know? In Jacksonville, Florida, Four hospitals operated by some of America's largest health care providers use Wastecorp HPE Series plunger pumps to transfer sewage.